Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 16 de 16
Filter
2.
Respir Care ; 67(9): 1129-1137, 2022 09.
Article in English | MEDLINE | ID: covidwho-1924458

ABSTRACT

BACKGROUND: Oxygen therapy via high-flow nasal cannula (HFNC) has been extensively used during the COVID-19 pandemic. The number of devices has also increased. We conducted this study to answer the following questions: Do HFNC devices differ from the original device for work of breathing (WOB) and generated PEEP? METHODS: Seven devices were tested on ASL 5000 lung model. Compliance was set to 40 mL/cm H2O and resistance to 10 cm H2O/L/s. The devices were connected to a manikin head via a nasal cannula with FIO2 set at 0.21. The measurements were performed at baseline (manikin head free of nasal cannula) and then with the cannula and the device attached with oxygen flow set at 20, 40, and 60 L/min. WOB and PEEP were assessed at 3 simulated inspiratory efforts (-5, -10, -15 cm H2O muscular pressure) and at 2 breathing frequencies (20 and 30 breaths/min). Data were expressed as median (first-third quartiles) and compared with nonparametric tests to the Optiflow device taken as reference. RESULTS: Baseline WOB and PEEP were comparable between devices. Over all the conditions tested, WOB was 4.2 (1.0-9.4) J/min with the reference device, and the relative variations from it were 0, -3 (2-4), 1 (0-1), -2 (1-2), -1 (1-2), and -1 (1-2)% with Airvo 2, G5, HM80, T60, V500, and V60 Plus devices, respectively, (P < .05 Kruskal-Wallis test). PEEP was 0.9 (0.3-1.5) cm H2O with Optiflow, and the relative differences were -28 (22-33), -41 (38-46), -30 (26-36), -31 (28-34), -37 (32-42), and -24 (21-34)% with Airvo 2, G5, HM80, T60, V500, and V60 Plus devices, respectively, (P < .05 Kruskal-Wallis test). CONCLUSIONS: WOB was marginally higher and PEEP marginally lower with devices as compared to the reference device.


Subject(s)
COVID-19 , Oxygen , Cannula , Humans , Oxygen Inhalation Therapy , Pandemics , Work of Breathing
3.
Medwave ; 22(3): e8724, 2022 Apr 29.
Article in Spanish, English | MEDLINE | ID: covidwho-1835563

ABSTRACT

Technological advances in mechanical ventilation have been essential to increasing the survival rate in intensive care units. Usually, patients needing mechanical ventilation use controlled ventilation to override the patients respiratory muscles and favor lung protection. Weaning from mechanical ventilation implies a transition towards spontaneous breathing, mainly using assisted mechanical ventilation. In this transition, the challenge for clinicians is to avoid under and over assistance and minimize excessive respiratory effort and iatrogenic diaphragmatic and lung damage. Esophageal balloon monitoring allows objective measurements of respiratory muscle activity in real time, but there are still limitations to its routine application in intensive care unit patients using mechanical ventilation. Like the esophageal balloon, respiratory muscle electromyography and diaphragmatic ultrasound are minimally invasive tools requiring specific training that monitor respiratory muscle activity. Particularly during the coronavirus disease pandemic, non invasive tools available on mechanical ventilators to monitor respiratory drive, inspiratory effort, and work of breathing have been extended to individualize mechanical ventilation based on patients needs. This review aims to identify the conceptual definitions of respiratory drive, inspiratory effort, and work of breathing and to identify non invasive maneuvers available on intensive care ventilators to measure these parameters. The literature highlights that although respiratory drive, inspiratory effort, and work of breathing are intuitive concepts, even distinguished authors disagree on their definitions.


Los avances tecnológicos de la ventilación mecánica han sido parte esencial del aumento de la sobrevida en las unidades de cuidados intensivos. Desde la conexión a la ventilación mecánica, comúnmente se utiliza ventilación controlada sin la consecuente participación de los músculos respiratorios del paciente, con el fin de favorecer la protección pulmonar. El retiro de la ventilación mecánica implica un periodo de transición hacia la respiración espontánea, utilizando principalmente ventilación mecánica asistida. En esta transición, el desafío de los clínicos es evitar la sub y sobre asistencia ventilatoria, minimizando el esfuerzo respiratorio excesivo, daño diafragmático y pulmonar inducidos por la ventilación mecánica. La monitorización con balón esofágico permite mediciones objetivas de la actividad muscular respiratoria en tiempo real, pero aún hay limitaciones para su aplicación rutinaria en pacientes ventilados mecánicamente en la unidad de cuidados intensivos. Al igual que el balón esofágico, la electromiografía de los músculos respiratorios y la ecografía diafragmática son herramientas que permiten monitorizar la actividad muscular de la respiración, siendo mínimamente invasivas y con requerimiento de entrenamiento específico. Particularmente, durante la actual pandemia de enfermedad por coronavirus se ha extendido el uso de herramientas no invasivas disponibles en los ventiladores mecánicos para monitorizar el impulso (drive), esfuerzo y trabajo respiratorio, para promover una ventilación mecánica ajustada a las necesidades del paciente. Consecuentemente, el objetivo de esta revisión es identificar las definiciones conceptuales de impulso, esfuerzo y trabajo respiratorio utilizadas en el contexto de la unidad de cuidados intensivos, e identificar las maniobras de medición no invasivas disponibles en los ventiladores de cuidados intensivos para monitorizar impulso, esfuerzo y trabajo respiratorio. La literatura destaca que, aunque los conceptos de impulso, esfuerzo y trabajo respiratorio se perciben intuitivos, no existe una definición clara. Asimismo, destacados autores los definen como conceptos diferentes.


Subject(s)
Pandemics , Work of Breathing , Critical Care , Humans , Respiration, Artificial , Ventilators, Mechanical , Work of Breathing/physiology
4.
Med Eng Phys ; 98: 36-43, 2021 12.
Article in English | MEDLINE | ID: covidwho-1540843

ABSTRACT

The outbreak of the ongoing coronavirus disease 2019 (COVID-19) pandemic has led to the recommended routine use of face masks to reduce exposure risk. In this study, the increase in work of breathing (WOB) imposed by face masks is theoretically studied for both normals and patients with obstructive and restrictive lung diseases at different levels of activity. The results show a significant increase in WOB due to face masks, which is more severe in higher activity levels. The added WOB is considerable during physical activity and may be intolerable for patients with preexisting lung disease and may contribute to inspiratory muscle fatigue and dyspnea. Moreover, in this study, the effects of the physical properties of a fibrous medium, including thickness, porosity, and fiber diameter, are analyzed on the particle filtration efficiency (PFE) and the added WOB. The relations between the physical properties of the fibrous medium and the added WOB and the PFE are shown on some contour plots as a quick and simple tool to select the desired physical properties for a single layer filter to ensure that the added WOB is comfortable while the PFE is sufficiently high.


Subject(s)
COVID-19 , Masks , Filtration , Humans , SARS-CoV-2 , Work of Breathing
5.
Crit Care ; 25(1): 327, 2021 09 08.
Article in English | MEDLINE | ID: covidwho-1403254

ABSTRACT

A helmet, comprising a transparent hood and a soft collar, surrounding the patient's head can be used to deliver noninvasive ventilatory support, both as continuous positive airway pressure and noninvasive positive pressure ventilation (NPPV), the latter providing active support for inspiration. In this review, we summarize the technical aspects relevant to this device, particularly how to prevent CO2 rebreathing and improve patient-ventilator synchrony during NPPV. Clinical studies describe the application of helmets in cardiogenic pulmonary oedema, pneumonia, COVID-19, postextubation and immune suppression. A section is dedicated to paediatric use. In summary, helmet therapy can be used safely and effectively to provide NIV during hypoxemic respiratory failure, improving oxygenation and possibly leading to better patient-centred outcomes than other interfaces.


Subject(s)
Interactive Ventilatory Support/methods , Noninvasive Ventilation/methods , Work of Breathing/physiology , COVID-19 , Humans , Monitoring, Physiologic/methods , Noninvasive Ventilation/instrumentation , Respiratory Insufficiency/therapy
6.
Pediatrics ; 148(6)2021 12 01.
Article in English | MEDLINE | ID: covidwho-1394629

ABSTRACT

A 3-month-old boy presented with a 3-hour history of a neck lump and difficulty breathing after 5 days of fever and reduced feeding. Pneumomediastinum with subcutaneous emphysema were identified, and the child was intubated because of severe work of breathing, requiring significant levels of oxygen and ventilatory pressure. Computed tomography chest scan revealed massive pneumomediastinum and significant bilateral parenchymal disease. The child deteriorated cardiovascularly, so the mediastinum was dissected by cardiothoracic surgeons and 2 drains were placed. The patient clinically improved with resolution of air leak over 2 days. A diagnosis of coronavirus disease 2019 pneumonia was confirmed.


Subject(s)
COVID-19/complications , Mediastinal Emphysema/etiology , SARS-CoV-2 , Subcutaneous Emphysema/etiology , COVID-19/diagnosis , COVID-19/diagnostic imaging , Humans , Infant , Male , Mediastinal Emphysema/diagnostic imaging , Rupture, Spontaneous , Subcutaneous Emphysema/diagnostic imaging , Tomography, X-Ray Computed , Work of Breathing
8.
Sports Health ; 13(5): 463-470, 2021.
Article in English | MEDLINE | ID: covidwho-1292155

ABSTRACT

BACKGROUND: While increased face mask use has helped reduce COVID-19 transmission, there have been concerns about its influence on thermoregulation during exercise in the heat, but consistent, evidence-based recommendations are lacking. HYPOTHESIS: No physiological differences would exist during low-to-moderate exercise intensity in the heat between trials with and without face masks, but perceptual sensations could vary. STUDY DESIGN: Crossover study. LEVEL OF EVIDENCE: Level 2. METHODS: Twelve physically active participants (8 male, 4 female; age = 24 ± 3 years) completed 4 face mask trials and 1 control trial (no mask) in the heat (32.3°C ± 0.04°C; 54.4% ± 0.7% relative humidity [RH]). The protocol was 60 minutes of walking and jogging between 35% and 60% of relative VO2max. Rectal temperature (Trec), heart rate (HR), temperature and humidity inside and outside of the face mask (Tmicro_in, Tmicro_out, RHmicro_in, RHmicro_out) and perceptual variables (rating of perceived exertion (RPE), thermal sensation, thirst sensation, fatigue level, and overall breathing discomfort) were monitored throughout all trials. RESULTS: Mean Trec and HR increased at 30- and 60-minute time points compared with 0-minute time points, but no difference existed between face mask trials and control trials (P > 0.05). Mean Tmicro_in, RHmicro_in, and humidity difference inside and outside of the face mask (ΔRHmicro) were significantly different between face mask trials (P < 0.05). There was no significant difference in perceptual variables between face mask trials and control trials (P > 0.05), except overall breathing discomfort (P < 0.01). Higher RHmicro_in, RPE, and thermal sensation significantly predicted higher overall breathing discomfort (r2 = 0.418; P < 0.01). CONCLUSION: Face mask use during 60 minutes of low-to-moderate exercise intensity in the heat did not significantly affect Trec or HR. Although face mask use may affect overall breathing discomfort due to the changes in the face mask microenvironment, face mask use itself did not cause an increase in whole body thermal stress. CLINICAL RELEVANCE: Face mask use is feasible and safe during exercise in the heat, at low-to-moderate exercise intensities, for physically active, healthy individuals.


Subject(s)
Body Temperature Regulation , COVID-19/prevention & control , Hot Temperature , Jogging/physiology , Masks , Walking/physiology , Adult , Cross-Over Studies , Female , Heart Rate , Humans , Humidity , Male , Perception , Physical Exertion/physiology , Random Allocation , SARS-CoV-2 , Thermosensing , Work of Breathing , Young Adult
10.
Anesthesiology ; 134(4): 518-525, 2021 04 01.
Article in English | MEDLINE | ID: covidwho-1010655

ABSTRACT

Clinicians who care for patients infected with coronavirus disease 2019 (COVID-19) must wear a full suite of personal protective equipment, including an N95 mask or powered air purifying respirator, eye protection, a fluid-impermeable gown, and gloves. This combination of personal protective equipment may cause increased work of breathing, reduced field of vision, muffled speech, difficulty hearing, and heat stress. These effects are not caused by individual weakness; they are normal and expected reactions that any person will have when exposed to an unusual environment. The physiologic and psychologic challenges imposed by personal protective equipment may have multiple causes, but immediate countermeasures and long-term mitigation strategies can help to improve a clinician's ability to provide care. Ultimately, a systematic approach to the design and integration of personal protective equipment is needed to improve the safety of patients and clinicians.


Subject(s)
COVID-19/prevention & control , Health Personnel/statistics & numerical data , Personal Protective Equipment/adverse effects , Work Performance/statistics & numerical data , Equipment Design , Hearing , Heat-Shock Response , Humans , SARS-CoV-2 , Speech , Visual Fields , Work of Breathing
11.
BMJ Case Rep ; 13(12)2020 Dec 13.
Article in English | MEDLINE | ID: covidwho-975661

ABSTRACT

A 59-year-old man presented to the emergency department with recent onset biphasic stridor, dyspnoea and increased work of breathing on the background of prolonged intubation for the novel COVID-19 2 months previously. Flexible laryngoscopy revealed bilateral vocal fold immobility with a soft tissue mass in the interarytenoid region. The patient's symptoms improved with oxygen therapy, nebulised epinephrine (5 mL; 1:10 000) and intravenous dexamethasone (3.3 mg). The following morning, the patient was taken to theatre, underwent suspension microlaryngoscopy and found to have bilateral fixation of the cricoarytenoid joints and a large granuloma in the interarytenoid area. He underwent cold steel resection of the granuloma and balloon dilatation between the arytenoids, with the hope of mobilising the joints. This failed and CO2 laser arytenoidectomy was performed on the left side. The stridor had resolved postoperatively, with normalisation of work of breathing and the patient was discharged home on the first postoperative day.


Subject(s)
COVID-19/therapy , Granuloma/surgery , Intubation, Intratracheal/adverse effects , Laryngeal Diseases/surgery , Constriction, Pathologic/etiology , Constriction, Pathologic/surgery , Dyspnea/etiology , Emergencies , Granuloma/etiology , Humans , Laryngeal Diseases/etiology , Larynx/pathology , Male , Middle Aged , Respiratory Sounds , SARS-CoV-2 , Work of Breathing
12.
Crit Care ; 24(1): 494, 2020 08 10.
Article in English | MEDLINE | ID: covidwho-704904

ABSTRACT

Deterioration of lung function during the first week of COVID-19 has been observed when patients remain with insufficient respiratory support. Patient self-inflicted lung injury (P-SILI) is theorized as the responsible, but there is not robust experimental and clinical data to support it. Given the limited understanding of P-SILI, we describe the physiological basis of P-SILI and we show experimental data to comprehend the role of regional strain and heterogeneity in lung injury due to increased work of breathing.In addition, we discuss the current approach to respiratory support for COVID-19 under this point of view.


Subject(s)
Coronavirus Infections/physiopathology , Disease Progression , Lung Injury/physiopathology , Pneumonia, Viral/physiopathology , Work of Breathing/physiology , COVID-19 , Coronavirus Infections/therapy , Critical Care , Humans , Lung Injury/etiology , Pandemics , Pneumonia, Viral/therapy , Randomized Controlled Trials as Topic , Respiration, Artificial
14.
Arch Dis Child Fetal Neonatal Ed ; 105(6): 669-671, 2020 Nov.
Article in English | MEDLINE | ID: covidwho-646314

ABSTRACT

BACKGROUND: The COVID-19 pandemic has raised concern for healthcare workers getting infected via aerosol from non-invasive respiratory support of infants. Attaching filters that remove viral particles in air from the expiratory limb of continuous positive airway pressure (CPAP) devices should theoretically decrease the risk. However, adding filters to the expiratory limb could add to expiratory resistance and thereby increase the imposed work of breathing (WOB). OBJECTIVE: To evaluate the effects on imposed WOB when attaching filters to the expiratory limb of CPAP devices. METHODS: Two filters were tested on three CPAP systems at two levels of CPAP in a mechanical lung model. Main outcome was imposed WOB. RESULTS: There was a minor increase in imposed WOB when attaching the filters. The differences between the two filters were small. CONCLUSION: To minimise contaminated aerosol generation during CPAP treatment, filters can be attached to expiratory tubing with only a minimal increase in imposed WOB in a non-humidified environment. Care has to be taken to avoid filter obstruction and replace filters as recommended.


Subject(s)
Continuous Positive Airway Pressure/instrumentation , Coronavirus Infections/prevention & control , Filtration/instrumentation , Infection Control/instrumentation , Pandemics/prevention & control , Pneumonia, Viral/prevention & control , Betacoronavirus , COVID-19 , Exhalation/physiology , Humans , Infant, Newborn , Intensive Care Units, Neonatal , Models, Anatomic , SARS-CoV-2 , Work of Breathing/physiology
15.
J Clin Monit Comput ; 35(1): 11-14, 2021 02.
Article in English | MEDLINE | ID: covidwho-611521

ABSTRACT

From home to intensive care units, innovations in pulse oximetry are susceptible to improve the monitoring and management of patients developing acute respiratory failure, and particularly those with the coronavirus disease 2019 (COVID-19). They include self-monitoring of oxygen saturation (SpO2) from home, continuous wireless SpO2 monitoring on hospital wards, and the integration of SpO2 as the input variable for closed-loop oxygen administration systems. The analysis of the pulse oximetry waveform may help to quantify respiratory efforts and prevent intubation delays. Tracking changes in the peripheral perfusion index during a preload-modifying maneuver may be useful to predict preload responsiveness and rationalize fluid therapy.


Subject(s)
COVID-19/blood , Monitoring, Physiologic/instrumentation , Oximetry/instrumentation , Oxygen/blood , Pandemics , SARS-CoV-2 , COVID-19/physiopathology , COVID-19/therapy , Critical Care , Fluid Therapy , Home Care Services , Humans , Monitoring, Ambulatory/instrumentation , Monitoring, Physiologic/methods , Monitoring, Physiologic/trends , Oximetry/methods , Oximetry/trends , Oxygen/administration & dosage , Oxygen Inhalation Therapy , Respiratory Insufficiency/blood , Respiratory Insufficiency/diagnosis , Respiratory Insufficiency/therapy , Work of Breathing
16.
Respir Physiol Neurobiol ; 280: 103474, 2020 09.
Article in English | MEDLINE | ID: covidwho-592467

ABSTRACT

AIM: To describe the response of breathing pattern and inspiratory effort upon changes in assist level and to assesss if changes in respiratory rate may indicate changes in respiratory muscle effort. METHODS: Prospective study of 82 patients ventilated on proportional assist ventilation (PAV+). At three levels of assist (20 %-50 %-80 %), patients' inspiratory effort and breathing pattern were evaluated using a validated prototype monitor. RESULTS: Independent of the assist level, a wide range of respiratory rates (16-35br/min) was observed when patients' effort was within the accepted range. Changing the assist level resulted in paired changes in inspiratory effort and rate of the same tendency (increase or decrease) in all but four patients. Increasing the level in assist resulted in a 31 % (8-44 %) decrease in inspiratory effort and a 10 % (0-18 %) decrease in respiratory rate. The change in respiratory rate upon the change in assist correlated modestly with the change in the effort (R = 0.5). CONCLUSION: Changing assist level results in changes in both respiratory rate and effort in the same direction, with change in effort being greater than that of respiratory rate. Yet, neither the magnitude of respiratory rate change nor the resulting absolute value may reliably predict the level of effort after a change in assist.


Subject(s)
Inhalation/physiology , Interactive Ventilatory Support/methods , Respiratory Rate/physiology , Work of Breathing/physiology , Aged , Aged, 80 and over , Airway Resistance , Critical Illness/therapy , Female , Humans , Lung Compliance , Male , Maximal Respiratory Pressures , Middle Aged , Tidal Volume
SELECTION OF CITATIONS
SEARCH DETAIL